Tender For corrigendum : procurement of electrical items under adp head 2025-26 - electrical items :, 33 kv pole top bracket 65x65x6 mm [galvanized] (3.58 kgs.), back clamp ( 50x6 mm) for 60kg rail pole[galvanized] (3.2 kgs.), 33kv v cross arm for (100x50x6 mm)[galvanized] (19.7 kgs.), support clamp for v cross arm for 60kg rail pole[galvanized] (1.6 kgs. each), angle/side stay clamp (50x6 mm) for 60kg rail pole [galvanized] (1.92 kgs.), d p channel support clamp ( 50x6 mm) feet (1 pair = 1 set) for 60kg rail pole[galvanized] (2.25 kgs. each), 33kv d p channel (100x50x6 mm) 2200 mm long [ galvanized] (45.5 kgs.) for ab switch & la, 33 kv cross bracing for dp[galvanized] (64.3 kgs.), support clamp for cross bracing for 60kg rail pole[galvanized] (2.5 kgs. each), structure for 33kv lightening arrestor [galvanized], structure for 33 kv isolator [galvanized], gantry column, girder structures for 33/11 kv pss for single transformer [galvanized], structure for post insulator for 33 kv [galvanized], danger board 33kv
Tender For corrigendum : rate contract for purchase of various items for repair of failed distribution transformers at nigams workshop - alu lv strip (size as required) dpc(variable with base date 1.6.25), alu hv bare (size as required) semc(variable with base date 1.6.25), cotton tape 1, sleeve 1 mm, 20 mil paper 30, 4 mil paper 24, 4 mil paper 26, 4 mil paper32, 4 mil paper 30, gum, 10 mil paper 20, core clamping insulation 2 mm, yoke various sizes mm, common block various sizes mm, oil duct various sizes mm thickness, stick various sizes mm, wooden spacer 45x45x15 mm, spacer 45x45x3 mm, ring 136x201x2 mm, delta flat 480x30x5 mm, lv chips 380x6x1 mm, foot plate paper 2 mm, p.c phase barrier various size mm, nut g.i.various sizes, washer g.i.various sizes, bolt g.i.various sizes, delta wire various sizes, earthing patti 1 mm thickness tinned copper 20mmx1mm, aluminium flat various sizes mm, delta patti, sleeve 8 mm, sleeve 4 mm, sleeve 6 mm, sleeve 10 mm, sleeve 12 mm, sleeve 1.5 mm, sleeve 2 mm, 1/2 nut g.i., 1/2 lock nut g.i., 1/2 washer g.i., flux, solder wire, copper brazing rod, aluminium brazing rod, brazing powder (l&t), crepe tape 1, 1/2 bakelite, 3/8 bakelite, hv bushing (porcelain,), hv bushing (metal part) complete set, lv bushing (porcelain,), lv bushing (metal part) complete set, ehv grade type-ii transformer oil ( with drum )(variable with base date 1.6.25), prv valve (virat), pvc cap 1/2, ci cap 1.25, paint (green/red/yellow/white/blue), thinner, zinc chromate, cork washer 12x32mm,110x74mmx50x28mm, top cover gasket 50x50x6 mm, oil gauge prismatic glass various size, oil gauge gasket various sizes, oil gauge washervarious sizes, oil gauge nut various sizes, vent pipe gasket 110x110x3 mm, hv clamp, aluminium member, m.s nuts,bolts,washers various sizes, mccb for box 32 amp, mccb for box 40 amp, mccb for box 63 amp, mccb for single phase 25amp, mccb for single phase 40amp, mccb for single phase 63amp, mccb box gasket 500x250x5 mm, silica gel breather, hv bmc, arcing horn with strip & nut bolt, candles mom, backalite sheet 0.50 mm thickness 60x60 mm, u clamp 70 x 50 x 70 mm prv, u clamp ci cap 50x50x50 mm, cloth, lt internal/ oil immerged circuit breaker assorted rating, holdtite, 1/4x2.5 bolt brecker, 1/4 nut brecker, aluminium lugs (various sizes), paint gun, engraving machine, hv farma (size as required), lv farma (size as required), grinder cutter wheel 4, lt bushing box
Tender For pproviding 200 kva transformer and ht lines in sector -8 u/e kurukshetra (balance work). (including six years defect liability period for transformer and three years free maintenance and defect liability period for other items, free of cost). recall
Tender For supply of misc em items d d--non - modular piano type domestic electrical switches as per is 3854 (q3) , piano type non modular domestic fan regulator as per is 11037 (q3) , piano type modular domestic electrical sockets - is 1293 (q3) , modular piano type domestic electrical switches as per is 3854 (q3) , electrical plugs (v2) isi marked to is 1293 (q2) , bayonet lampholders (v2) isi marked to is 1258 (q2) , piano type non modular domestic electrical sockets - is 1293 (q3) , modular fan regulator 2 module , celing rose , switch 5 6 amp 2 way , switch socket combined 6 amp , switch socket combined 16 amp , heat shrinkable straight through 95 sqmm x 3 core, 11 kv end terminatrion. , heat shrinkable straight through 185 sqmm x 3 core, 11 kv end terminatrion. , heat shrinkable straight through 120 sqmm x 3 core, 11 kv end terminatrion. , heat shrinkable cable joint 10 sqmm 2 core , heat shrinkable cable joint 16 sqmm 2 core , heat shrinkable cable joint 10 sqmm , heat shrinkable cable joint 16 sqmm , heat shrinkable cable joint 25 sqmm , heat shrinkable cable joint 35 sqmm , heat shrinkable cable joint 50 sqmm , heat shrinkable cable joint 70 sqmm , heat shrinkable cable joint 95 sqmm , heat shrinkable cable joint 120 sqmm , heat shrinkable cable joint 150 sqmm , heat shrinkable cable joint 185 sqmm , heat shrinkable cable joint 240 sqmm , condensor 2. 5 mfd , condensor 4 mfd , ding dong bell , buzzer electric , insulationtape 15 mm x 25 mtr long , insulationtape 20 mm x 25 mtr long , insulation tape 25 mm x 25 mtr long , ht tape , pvc casing caping 20mm , pvc conduite pipe 25mm , pvc conduite pipe 32mm , pvc saddle clip for cable 6 mm , pvc saddle clip for cable 25 mm , heating element 2000w cup or thread type , heating element 2000w , heating element 1500w , 3 kw heating element , gasket for transformer sheet , foam for gap filling in electrical panel db and 1 ltr pkt , crc liquid for preventing corrosingn and 500 ml pkt , geyser element 2 kv , ac gang box switch socket and top with mcb 25 amp , change over switch 100 amp , change over switch 200 amp , change over switch 400 amp , contactor mnx-50 , contactor mnx-70 , contactor mnx-95 , modular surface mounted gang box 3 module , modular surface mounted gang box 6 module , modular surface mounted gang box 18 module , modular cover plate 3 module with frame , modular cover plate 6 module with frame , cotton waste , pig lead , lead acid battery 12 v 90_100 ah , lead acid battery 12 v 90_150 ah , lead acid battery 12 v 90_180 ah , thermostate for geyser , astronomical timer for street light control , compressor 220-280 v, weight 18 kg for split ac 1. 5 or 2 tr , compressor 50 plus 4 or 50 plus 6 mfd rotary type suitable for split ac 1. 5 or 2 tr , electronic pcb plate for split and window ac suitable for 1. 5 or 2 tr , solar street light ng series 40 w , magnum grand pwb , transformer oil //bid details2 / 82
Tender For up-gradation / supply, replacement and etc work of new numerical relay in-place of alstom make old electromagnetic type protection relays in 6.6kv ht switchgear at unit 1 , cw swgr, ahp and chp swgr stg.-i, sstps, suratgarh - supply items, supply of numerical multifunction 6.6kv ht motor protection relay, aux. voltage- 220 v dc (as per technical specification, scope of work), supply of numerical multifunction 6.6kv ht feeder protection relay (suitable for incomer, transformer & outgoing feeder), aux. voltage- 220 v dc (as per technical specification, scope of work), sub total (sr.no.1.01 to 1.02), total packing & forwarding charges, sub total of supply+p&f (including gst), total freight charges upto stps site, total insurance charges upto stps site, any other charges/taxes, sub total (sr.1.05+1.06+1.07+1.08), etc, work of etc and replacement of all the numerical multifunction relays (78 nos.) (6.6kv ht feeder protection and 6 .6kv ht motor protection) to existing electromagnetic relays (retrofitting work) (as per scope of work of tender document), total of etc (including gst), any other charges, total of etc charges (2.02+2.03), net total (supply+etc)
Tender For corrigendum : special repair to replacement of ber transformer and diesel generator set and allied items under ge (a) gandhinagar at gandhinagar military station
Tender For supply of contactor k44 for 60 kva transformer, rated current: 95 amps, rated voltage: 690 v ac, main pole: 4, aux contact: 1no + 1nc control voltage: 230 v ac (168 v ac 300 v ac means 230 v ac +/- 30 percent ) with surge suppressor as per rdso spec no. rdso/pe/spec/ ac/0184-2015 (rev - 1) and as per update of common bom items issued by rdso lr.no. el/7.1.108/mssbc, dt 17/09/21 to abb model no. af 116b-40, schneider model no. lc1d1150046m5 + la4da2u only accepted.